Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Optom Vis Sci ; 95(6): 515-522, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-29787490

RESUMO

SIGNIFICANCE: New bitangential mini-scleral lens designs provide a highly precise fit, follow the scleral shape, are comfortable to wear, and can correct residual astigmatism. This new scleral lens design complements the arsenal of medical contact lenses available to eye care practitioners. PURPOSE: The aim of this study was to evaluate the subjective and objective performance of a new mini-scleral lens design with a bitangential periphery. METHODS: In this observational study, data were collected for up to 15 months (median, 84 days; interquartile range, 76 days) from the left eyes of 133 patients fitted with this newly designed lens. Data were recorded during regular visits at Visser Contact Lens Practice's scleral lens clinics: diagnosis, clinical indication for scleral lenses, previous contact lens type, subjective performance, horizontal visible iris diameter, corrected distance visual acuity, and scleral lens fitting characteristics. RESULTS: The most common indication was keratoconus (45%), followed by irregular astigmatism (22%), keratoplasty (16.5%), ocular surface disease (13.5%), and other forms of irregular astigmatism (3%). The majority of patients (79%) scored comfort as either a 4 or 5 (out of 5), and 82% wore their lenses 12 hours or longer a day. Most lenses (81%) had a diameter of 16 mm (median, 16 mm; range, 15.5 to 17 mm) and were composed of Boston XO2 (46%), Menicon Z (44%), Boston XO (9%), or Boston Equalens II (1%). The median corrected distance visual acuity was 0.022 logarithm of the minimal angle of resolution (interquartile range, 0.155). The fitting characteristics revealed optimal values for centration and movement in 91% and 83%, respectively. Finally, the median stabilization axis was 50 degrees. CONCLUSIONS: New mini-scleral lenses with bitangential peripheral geometry yield satisfactory clinical results and good subjective performance and are therefore an effective option for managing patients who have irregular astigmatism or other corneal pathology.


Assuntos
Lentes de Contato , Ceratocone/terapia , Erros de Refração/terapia , Esclera , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Ceratocone/fisiopatologia , Ceratoplastia Penetrante , Masculino , Pessoa de Meia-Idade , Desenho de Prótese , Ajuste de Prótese , Erros de Refração/fisiopatologia , Acuidade Visual/fisiologia
3.
Optom Vis Sci ; 90(10): 1078-85, 2013 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-23974663

RESUMO

PURPOSE: To evaluate the clinical results of a new scleral lens design with a bitangential (nonrotationally symmetrical) periphery. METHODS: All the necessary data were obtained during the 1-year study period. The bitangential scleral lenses were fitted and monitored according to a standardized fitting methodology. They were cut by precise submicron lathing from high-oxygen-permeable materials (including 10 scleral lenses from Menicon Z material). Subjective performance, visual acuity, and scleral lens-fitting characteristics were recorded after a median of 9.4 weeks (range, 3 weeks to 1 year). RESULTS: Diagnoses in the 213 eyes (in 144 patients) were keratoconus (n = 121 eyes; 56.8%), ocular surface diseases (n = 31 eyes; 14.6%), penetrating keratoplasty (n = 29 eyes; 13.6%), and other forms of irregular astigmatism (n = 28 eyes; 13.1%). Many patients (164 lenses; 77.0%) gave high ratings for comfort. The most common diameter was 20.0 mm (162 lenses; 76.1%) (range, 18.5 to 21.5 mm). Median decimal best-corrected visual acuity with the bitangential scleral lenses was 0.8 (equivalent to Snellen 20/25) (range, 0 to 1.5). Most bitangential scleral lenses showed good fitting characteristics: optimal values were seen for lens movement (208 lenses; 97.7%) and lens position (208 lenses; 97.7%). Median central corneal clearance was 0.2 mm; clearances differed in the four peripheral directions. The median stabilization axis was 140 degrees (range, 0 to 180 degrees) in the right eyes and 60 degrees (range, 0 to 180 degrees) in the left eyes. CONCLUSIONS: The bitangential scleral lens-fitting and performance characteristics were clear and effective for the health professional and the patient. The high-oxygen-permeable material Menicon Z may, in theory, be of benefit to corneas with a high oxygen demand.


Assuntos
Lentes de Contato , Doenças da Córnea/terapia , Esclera , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Criança , Doenças da Córnea/fisiopatologia , Feminino , Humanos , Ceratoplastia Penetrante , Masculino , Pessoa de Meia-Idade , Satisfação do Paciente , Desenho de Prótese , Ajuste de Prótese , Acuidade Visual/fisiologia , Adulto Jovem
4.
Eye Contact Lens ; 33(1): 13-20, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17224674

RESUMO

PURPOSE: To evaluate the indications for modern scleral lenses and their clinical performance in patients who were fitted with scleral lenses at the authors' practices. METHODS: In this cross-sectional survey, all the necessary data were obtained at the first follow-up visit during the 5-month study period. There were four types of scleral lenses: spherical, front-surface toric, back-surface toric, and bitoric. The preformed scleral lens fitting technique developed at Visser Contact Lens Practice was used in all patients. The lenses were cut by precise Sub Micron Lathing from a Boston Equalens II blank at Procornea. Visual acuity and slitlamp findings were recorded. A specially designed classification for scleral lens fitting was used to investigate clinical performance. RESULTS: The largest proportion of the 178 patients (284 eyes) were diagnosed with keratoconus (143 [50.4%] eyes) followed by postpenetrating keratoplasty (56 [19.7%] eyes). The remaining diagnoses were irregular astigmatism, keratitis sicca, corneal dystrophy, and multiple diagnoses. The ratio of spherical to back-surface toric designs was 1:1.1. Clinical examination showed sharp increases in visual acuity (median increase, 0.45) and safe physiologic responses of the anterior eye. All the patients could continue to wear scleral lenses, with 79.2% with the same lens parameters. CONCLUSIONS: Several types of corneal abnormality were managed successfully with modern scleral lenses. The main indication was optical correction of an irregular corneal surface. Satisfactory clinical performance meant that all the patients could continue to wear their scleral lenses.


Assuntos
Lentes de Contato/normas , Síndromes do Olho Seco/reabilitação , Ceratocone/reabilitação , Cuidados Pós-Operatórios/instrumentação , Esclera , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Estudos Transversais , Síndromes do Olho Seco/cirurgia , Desenho de Equipamento , Feminino , Seguimentos , Humanos , Ceratocone/cirurgia , Ceratoplastia Penetrante , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento , Acuidade Visual
5.
Eye Contact Lens ; 33(1): 21-5, 2007 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-17224675

RESUMO

PURPOSE: To evaluate the subjective performance of modern scleral lenses in patients of the clinics of Visser Contact Lens Practice. METHODS: In this cross-sectional survey, all the necessary data were collected at the first follow-up visit during the 5-month study period. In accordance with the preformed fitting technique developed at Visser Contact Lens Practice, four types of scleral lenses were used: spherical, front-surface toric, back-surface toric, and bitoric. Subjective performance was investigated during an interview that included the use of a five-point Likert scale and by means of a questionnaire supplemented by a 100-mm visual analog scale (VAS). RESULTS: The interview and questionnaire showed high scores for patient satisfaction with the current scleral lens in the 178 patients (284 eyes) (median score, 4; range Likert scale, 1-5; median score, >or=75; range VAS, 1-100). Significant increases in scores were seen with the current scleral lens compared to the former correction: 78.9% for comfort, 78.2% for visual quality, and 87.7% for overall satisfaction (n=284 eyes) (P<0.001). In the 99 eyes that switched from back-surface spherical to back-surface toric designs, the following significant increases were seen: 61.6%, 37.4%, and 65.7%, respectively (P<0.001). CONCLUSIONS.: High patient satisfaction was seen with all the modern scleral lens designs in the management of several forms of corneal abnormality. The interview showed differences in comfort, visual quality, and overall satisfaction in favor of the back-surface toric designs compared to the back-surface spherical designs.


Assuntos
Lentes de Contato/normas , Doenças da Córnea/reabilitação , Satisfação do Paciente , Esclera , Estudos Transversais , Desenho de Equipamento , Seguimentos , Humanos , Estudos Prospectivos , Inquéritos e Questionários , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...